+The important thing to remember is that if you specify a 'reject'
+filter (all the lines in it say 'reject/spots' (for instance) then if
+a spot comes in that doesn't match any of the lines then you will get
+it BUT if you specify an 'accept' filter then any spots that don't
+match are dumped. For example if I have a one line accept filter:-
+
+ accept/spots freq vhf and (by_zone 14,15,16 or call_zone 14,15,16)
+
+then automatically you will ONLY get VHF spots from or to CQ zones 14
+15 and 16. If you set a reject filter like:
+
+ reject/spots freq hf/cw
+
+Then you will get everything EXCEPT HF CW spots, If you am interested in IOTA
+and will work it even on CW then you could say:-
+
+ reject/spots freq hf/cw and not info iota
+
+But in that case you might only be interested in iota and say:-
+
+ accept/spots not freq hf/cw or info iota
+
+which is exactly the same. You should choose one or the other until
+you are confortable with the way it works. Yes, you can mix them
+(actually you can have an accept AND a reject on the same line) but
+don't try this at home until you can analyse the results that you get
+without ringing up the sysop for help.
+
+You can arrange your filter lines into logical units, either for your
+own understanding or simply convenience. I have one set frequently:-
+
+ reject/spots 1 freq/cw
+ reject/spots 2 freq 50000/1400000 not (by_zone 14,15,16 or call_zone 14,15,16)
+
+What this does is to ignore all HF CW spots (being a class B I can't
+read any CW and couldn't possibly be interested in HF :-) and also
+rejects any spots on VHF which don't either originate or spot someone
+in Europe.
+
+This is an exmaple where you would use the line number (1 and 2 in
+this case), if you leave the digit out, the system assumes '1'. Digits
+'0'-'9' are available.
+
+You can leave the word 'and' out if you want, it is implied. You can
+use any number of brackets to make the 'expression' as you want
+it. There are things called precedence rules working here which mean
+that you will NEED brackets in a situation like line 2 because,
+without it, will assume:-
+
+ (freq 50000/1400000 and by_zone 14,15,16) or call_zone 14,15,16
+
+annoying, but that is the way it is. If you use OR - use
+brackets. Whilst we are here CASE is not important. 'And BY_Zone' is
+just 'and by_zone'.
+
+If you want to alter your filter you can just redefine one or more
+lines of it or clear out one line. For example:-
+
+ reject/spots 1 freq/ssb
+
+or
+
+ clear/spots 1
+
+To remove the filter in its entirty:-
+
+ clear/spots all
+
+ADVANCED USERS:-
+
+Once you are happy with the results you get, you may like to experiment.
+
+my example that filters hf/cw spots and accepts vhf/uhf spots from EU
+can be written with a mixed filter, eg:
+
+ rej/spot freq hf/cw
+ acc/spot freq 0/30000
+ acc/spot 2 freq 50000/1400000 and (by_zone 14,15,16 or call_zone 14,15,16)
+
+each filter slot actually has a 'reject' slot and an 'accept'
+slot. The reject slot is executed BEFORE the accept slot.
+
+It was mentioned earlier that after a reject test that doesn't match,
+the default for following tests is 'accept', the reverse is true for
+'accept'. In the example what happens is that the reject is executed
+first, any non hf/cw spot is passed to the accept line, which lets
+thru everything else on HF.
+
+The next filter line lets through just VHF/UHF spots from EU.
+